| Type of Material: | Thesis |
| Title: | Design development and numerical characterization of indirect domestic hybrid solar dryer |
| Researcher: | Sharma, Mukul |
| Guide: | Atheaya, Deepali |
| Department: | Department of Mechanical and Aerospace Engineering |
| Publisher: | Bennett University |
| Place: | Greater Noida |
| Year: | 2023 |
| Language: | English |
| Subject: | Engineering | Engineering and Technology | Engineering Mechanical | Mechanical engineering | Engineering and Technology |
| Dissertation/Thesis Note: | PhD; Department of Mechanical and Aerospace Engineering, Bennett University, Greater Noida; 2023 |
| Fulltext: | Shodhganga |
| 003 | IN-AhILN | |
| 005 | 2026-10-14 14:51:58 | |
| 008 | __ | 261014t2023||||ii#||||g|m||||||||||eng|| |
| 035 | __ | |a(IN-AhILN)th_464159 |
| 040 | __ | |dIN-AhILN|aBENN_201310 |
| 041 | __ | |aeng |
| 100 | __ | |eResearcher|aSharma, Mukul |
| 110 | __ | |aDepartment of Mechanical and Aerospace Engineering|0U-0890|dGreater Noida|bBennett University|ein |
| 245 | __ | |aDesign development and numerical characterization of indirect domestic hybrid solar dryer |
| 260 | __ | |aGreater Noida|c2023|bBennett University |
| 300 | __ | |axxiv; 160 |
| 502 | __ | |d2023|bPhD|cDepartment of Mechanical and Aerospace Engineering, Bennett University, Greater Noida |
| 518 | __ | |d2023|oDate of Award |
| 518 | __ | |d2020|oDate of Registration |
| 518 | __ | |oDate of Completion|d2023 |
| 520 | __ | |aA novel design of domestic hybrid solar dryer system has been proposed and analysed with Computational Fluid Dynamics (CFD) using Ansys Fluent 19.2 software under unload condition. Further, Experiments under unload and load conditions were performed at Delhi Technological University (DTU), Delhi in the month of November 2021. From unload experimentation, thermal performance parameters namely thermal efficiency, HUF (heat utilisation factor) and COP (coefficient of performance) of solar collector in indirect type domestic hybrid solar dryer were evaluated. The maximum values of thermal efficiency, HUF, and COP were noted as 59%, 0.68, and 0.32 at 13:00 hours. The theoretical results were in fair agreement with experimental results as evaluated using linear regression analysis. Moreover, ITDHSD (indirect type domestic hybrid solar dryer) was found superior to other developed solar dryers in terms of maximum collector thermal efficiency. From experiments under load condition, various parameters such as thermal |
| 650 | __ | |aMechanical engineering|2UGC |
| 650 | __ | |aEngineering and Technology|2AIU |
| 653 | __ | |aEngineering |
| 653 | __ | |aEngineering and Technology |
| 653 | __ | |aEngineering Mechanical |
| 700 | __ | |aAtheaya, Deepali|eGuide |
| 856 | __ | |uhttp://shodhganga.inflibnet.ac.in/handle/10603/557669|yShodhganga |
| 905 | __ | |afromsg |
User Feedback Comes Under This section.