| Type of Material: | Thesis |
| Title: | Surface decorated magnetic particles in combination with isothermal nucleic acid amplification for rapid pathogen detection |
| Researcher: | Tripathi, Sayantan |
| Guide: | Ghosh, Souradyuti |
| Department: | Department of Chemistry |
| Publisher: | Bennett University |
| Place: | Greater Noida |
| Year: | 2022 |
| Language: | English |
| Subject: | Chemistry | Chemistry Analytical | Physical Sciences | Chemistry | Physical and Basic Sciences |
| Dissertation/Thesis Note: | PhD; Department of Chemistry, Bennett University, Greater Noida; 2022 |
| Fulltext: | Shodhganga |
| 003 | IN-AhILN | |
| 005 | 2026-10-14 12:05:47 | |
| 008 | __ | 261014t2022||||ii#||||g|m||||||||||eng|| |
| 035 | __ | |a(IN-AhILN)th_464148 |
| 040 | __ | |dIN-AhILN|aBENN_201310 |
| 041 | __ | |aeng |
| 100 | __ | |eResearcher|aTripathi, Sayantan |
| 110 | __ | |aDepartment of Chemistry|0U-0890|dGreater Noida|bBennett University|ein |
| 245 | __ | |aSurface decorated magnetic particles in combination with isothermal nucleic acid amplification for rapid pathogen detection |
| 260 | __ | |aGreater Noida|c2022|bBennett University |
| 502 | __ | |bPhD|d2022|cDepartment of Chemistry, Bennett University, Greater Noida |
| 518 | __ | |oDate of Award|d2023 |
| 518 | __ | |oDate of Completion|d2022 |
| 520 | __ | |aNucleic acid extraction from clinical samples followed by nucleic acid amplification tests (NAATs) is the key step of conventional molecular diagnostics. Recently, isothermal nucleic acid amplification tests (iNAATs) draw the attention of scientists. These techniques have a significant advantage over conventional NAATs as the detection of the amplicons by iNAATs can be pushed forward using a thermal cycler-free manner, therefore enabling field detection. It helps obtain rapid, quantitative results either in the laboratory or, more importantly, in a resource-limited area. Despite these advantages, prior nucleic acid extraction from the clinical sample is necessary for both NAATs and iNAATs, which need high-cost instruments, a centralized lab, and highly trained personnel. Microfluidic devices can overcome the issue of prior nucleic acid extraction but the complex fabrication procedure of the analytical device makes it non-compatible in the resource-constrained settings by the end-users. Immunoassays could al |
| 650 | __ | |aChemistry|2UGC |
| 650 | __ | |aPhysical and Basic Sciences|2AIU |
| 653 | __ | |aChemistry |
| 653 | __ | |aChemistry Analytical |
| 653 | __ | |aPhysical Sciences |
| 700 | __ | |aGhosh, Souradyuti|eGuide |
| 856 | __ | |uhttp://shodhganga.inflibnet.ac.in/handle/10603/515229|yShodhganga |
| 905 | __ | |afromsg |
User Feedback Comes Under This section.