Title : Investigation On RC Beams Strengthened With Hybrid Fibre Reinforced Polymer Laminates

Type of Material: Thesis
Title: Investigation On RC Beams Strengthened With Hybrid Fibre Reinforced Polymer Laminates
Researcher: Hemapriya,M
Guide: Venkata Krishnaiah, R
Department: Department of Civil Engineering
Publisher: Bharath University, Chennai
Place: Chennai
Year: 2022
Language: English
Subject: Engineering
Engineering and Technology
Engineering Civil
Civil Engineering
Engineering and Technology
Dissertation/Thesis Note: PhD; Department of Civil Engineering, Bharath University, Chennai, Chennai; 2022; D18CE501
Fulltext: Shodhganga

00000000ntm a2200000ua 4500
001455143
003IN-AhILN
0052024-09-23 15:49:59
008__240923t2022||||ii#||||g|m||||||||||eng||
035__|a(IN-AhILN)th_455143
040__|aBHAU_600073|dIN-AhILN
041__|aeng
100__|aHemapriya,M|eResearcher
110__|aDepartment of Civil Engineering|bBharath University, Chennai|dChennai|ein|0U-0446
245__|aInvestigation On RC Beams Strengthened With Hybrid Fibre Reinforced Polymer Laminates
260__|aChennai|bBharath University, Chennai|c2022
300__|dDVD
502__|cDepartment of Civil Engineering, Bharath University, Chennai, Chennai|d2022|oD18CE501|bPhD
518__|d2022|oDate of Award
520__|aA new retrofitting technique based on the combination of GFRP and CFRP laminates which are compatible with concrete is presently developed, this technique overcomes some of the draw backs like the mismatch of their tensile strength and the stiffness with that of the concrete element being retrofitted. This paper describes the performance of the reinforced concrete beams strengthened with a thin layer of CFRP laminate over GFRP laminate layer. The special characteristics of Hybrid laminates (Glass and Carbon) make them specifically suitable for repairing and retrofitting existing concrete structural elements. It will be shown that there is noticeable increase in capacity of reinforced beams strengthened by using Hybrid laminates adhesive bonded to the prepared surface of the beams. Three patterns of wrapping followed for the study ie.U-Wrap pattern, Bottom/soffit of the beam throughout its length and at sides of the beam for the entire length of the beam. Un-strengthened beams ie. Control beams failed at 75