Title : Volumetric Bone Analysis and Implant Insertion Torque Load Analysis for Dental Implants in Mandible Using CBCT Images

Type of Material: Thesis
Title: Volumetric Bone Analysis and Implant Insertion Torque Load Analysis for Dental Implants in Mandible Using CBCT Images
Researcher: Venkatakrishnan,C J
Guide: BHUMINATHAN, S
Department: Faculty of Dental Sciences
Publisher: Bharath University, Chennai
Place: Chennai
Year: 2018
Language: English
Subject: Clinical Medicine
Clinical Pre Clinical and Health
Dentistry Oral Surgery and Medicine
Medical Sciences
Medical and Health Sciences
Dissertation/Thesis Note: PhD; Faculty of Dental Sciences, Bharath University, Chennai, Chennai; 2018; D12DS002
Fulltext: Shodhganga

00000000ntm a2200000ua 4500
001454798
003IN-AhILN
0052024-09-19 11:02:36
008__240919t2018||||ii#||||g|m||||||||||eng||
035__|a(IN-AhILN)th_454798
040__|aBHAU_600073|dIN-AhILN
041__|aeng
100__|aVenkatakrishnan,C J|eResearcher
110__|aFaculty of Dental Sciences|bBharath University, Chennai|dChennai|ein|0U-0446
245__|aVolumetric Bone Analysis and Implant Insertion Torque Load Analysis for Dental Implants in Mandible Using CBCT Images
260__|aChennai|bBharath University, Chennai|c2018
300__|dDVD
502__|bPhD|cFaculty of Dental Sciences, Bharath University, Chennai, Chennai|d2018|oD12DS002
520__|aOsteoporotic patients require particular attention to their implant site bone quality as an indication of prognosis and may require modified surgical technique Insertion Torque (IT). The purpose of this study to test whether IT is significantly correlated with bone density or not, as assessed by the cone-beam computed tomography (CBCT) in a group of osteopenic and osteoporotic patients. A total of 30 patients were included in the study. The mandibular second premolar region was chosen as the site of investigation to prevent variability in surgical implant placement technique in different locations affecting bone mineral density (BMD). Partially, edentulous female patients between 51 and 60 years of age who were scheduled to receive implant placement were recruited for the study. CBCT (Master Series 3D Dental Imaging) was used for preoperative evaluation of the jaws for each patient. Materialise s Interactive Medical Image Control System (MIMICS) was used to process stacks of 2D images from CBCT. Finite elem
650__|aMedical Sciences|2UGC
650__|aMedical and Health Sciences|2AIU
653__|aClinical Medicine
653__|aClinical Pre Clinical and Health
653__|aDentistry Oral Surgery and Medicine
700__|aBHUMINATHAN, S|eGuide
856__|uhttp://shodhganga.inflibnet.ac.in/handle/10603/319862|yShodhganga
905__|afromsg

User Feedback Comes Under This section.