Title : Studies related to the operation of solid rotor alternator

Type of Material: Thesis
Title: Studies related to the operation of solid rotor alternator
Researcher: Babu, Golturu Suresh
Guide: Choudhury, U. K.
Das, G Tulasi Ram
Department: Department of Electronics and Communication Engineering
Publisher: Jawaharlal Nehru Technological University, Hyderabad
Place: Hyderabad
Year: 2013
Language: English
Subject: Alternator
Operation
Rotor
Solid
Studies
Electronics and Communication Engineering
Engineering and Technology
Dissertation/Thesis Note: PhD; Department of Electronics and Communication Engineering, Jawaharlal Nehru Technological University, Hyderabad, Hyderabad; 2013
Fulltext: Shodhganga

00000000ntm a2200000ua 4500
001453953
003IN-AhILN
0052024-07-10 14:57:00
008__240710t2013||||ii#||||g|m||||||||||eng||
035__|a(IN-AhILN)th_453953
040__|aJNTU_500028|dIN-AhILN
041__|aeng
100__|aBabu, Golturu Suresh|eResearcher
110__|aDepartment of Electronics and Communication Engineering|bJawaharlal Nehru Technological University, Hyderabad|dHyderabad|ein|0U-0017
245__|aStudies related to the operation of solid rotor alternator
260__|aHyderabad|bJawaharlal Nehru Technological University, Hyderabad|c2013
300__|a167 p.|c-|dNone
500__|aReferences p. 125-129 Appendix p. 130-167
502__|cDepartment of Electronics and Communication Engineering, Jawaharlal Nehru Technological University, Hyderabad, Hyderabad|d2013|bPhD
520__|aIndian electrical industries supply industrial alternators for rectifier loads, arc furnace loads and thyristor load applications to various customers. These synchronous machines along with rectifier newlineloads are also used in HVDC system and AC exciters. In such cases the harmonics will be injected in from the supply side of the alternator making the generator line current distorted to trapezoidal waveform. newlineThese harmonics increases the losses in stator conductors. Negative-sequence currents which are due to load imbalance, will also induce 100Hz components in the field and damper windings. The solid iron rotor in case of large synchronous machines will have induced currents due to harmonic and unbalanced loads which cause additional losses and consequently temperature rise. This thesis emphasizes about the design aspects, constructional features and newlineexperimentation on Solid Rotor Alternator (SRA) to study its behavior under harmonic loads and unbalanced loads. newline
650__|aElectronics and Communication Engineering|2UGC
650__|aEngineering and Technology|2AIU
653__|aAlternator
653__|aOperation
653__|aRotor
653__|aSolid
653__|aStudies
700__|aChoudhury, U. K.|eGuide
700__|eCo-Guide|aDas, G Tulasi Ram
856__|uhttp://shodhganga.inflibnet.ac.in/handle/10603/19490|yShodhganga
905__|afromsg

User Feedback Comes Under This section.