Title : An Experimental evaluation of two level and multilevel inverters used for speed control of induction motor and study of common mode voltage present in both cases

Type of Material: Thesis
Title: An Experimental evaluation of two level and multilevel inverters used for speed control of induction motor and study of common mode voltage present in both cases
Researcher: Muralidhara, B.
Guide: Ramachandran, A.
Department: Department of Electrical and Electronics Engineering
Publisher: Jawaharlal Nehru Technological University, Hyderabad
Place: Hyderabad
Year: 2013
Language: English
Subject: Evaluation
Experimental
Induction
Multilevel
Electrical Engineering
Engineering and Technology
Dissertation/Thesis Note: PhD; Department of Electrical and Electronics Engineering, Jawaharlal Nehru Technological University, Hyderabad, Hyderabad; 2013
Fulltext: Shodhganga

00000000ntm a2200000ua 4500
001453876
003IN-AhILN
0052024-07-03 17:29:11
008__240703t2013||||ii#||||g|m||||||||||eng||
035__|a(IN-AhILN)th_453876
040__|aJNTU_500028|dIN-AhILN
041__|aeng
100__|aMuralidhara, B.|eResearcher
110__|aDepartment of Electrical and Electronics Engineering|bJawaharlal Nehru Technological University, Hyderabad|dHyderabad|ein|0U-0017
245__|aAn Experimental evaluation of two level and multilevel inverters used for speed control of induction motor and study of common mode voltage present in both cases
260__|aHyderabad|bJawaharlal Nehru Technological University, Hyderabad|c2013
300__|a178 p.|dNone|c-
500__|aReferences p. 148-154 appendixp. 155-178
502__|cDepartment of Electrical and Electronics Engineering, Jawaharlal Nehru Technological University, Hyderabad, Hyderabad|d2013|bPhD
520__|aVariable speed inverter fed Induction Motor (IM) drives are increasingly used in many commercial and industrial applications, the newlinehigh frequency switching operation (2 to 20kHz) has improved the system efficiency, energy saving and ease in control. But with high speed switching device such as MOSFET or IGBT, Inverter fed IM drives have newlinethe drawbacks like 1. Common mode voltage (CM) 2. Rotor shaft voltage and Bearing current etc. The CM voltage is the voltage between the star point of IM stator winding to ground. This voltage always disturbs the newlinenearby measuring and controlling circuits. In a balanced sinusoidal 3-phase system, the 3-phase voltage vector sum is always equal to zero. But in the case of PWM inverter switched from same DC voltage source newlineconverted into 3-phase voltages, it is difficult to make the sum of the 3- newlinephase output voltages equal to zero hence the voltage between star point of stator winding of an IM to ground will exist which has to be min
650__|aElectrical Engineering|2UGC
650__|aEngineering and Technology|2AIU
653__|aEvaluation
653__|aExperimental
653__|aInduction
653__|aMultilevel
700__|aRamachandran, A.|eGuide
856__|uhttp://shodhganga.inflibnet.ac.in/handle/10603/19048|yShodhganga
905__|afromsg