Type of Material: | Thesis |
Title: | High quality rectifiers with reduced thd for enhanced mains power quality |
Researcher: | Reddy, Baddam Anantha |
Guide: | Das, G Tulasi Ram |
Department: | Department of Electrical and Electronics Engineering |
Publisher: | Jawaharlal Nehru Technological University, Hyderabad |
Place: | Hyderabad |
Year: | 2012 |
Language: | English |
Subject: | Enhanced | Mains | Power | Quality | Rectifiers |
Dissertation/Thesis Note: | PhD; 0503PH0708 |
Fulltext: | Shodhganga |
000 | 00000ntm a2200000ua 4500 | |
001 | 453718 | |
003 | IN-AhILN | |
005 | 2024-06-11 17:53:59 | |
008 | __ | 240611t2012||||ii#||||g|m||||||||||eng|| |
035 | __ | |a(IN-AhILN)th_453718 |
040 | __ | |aJNTU_500028|dIN-AhILN |
041 | __ | |aeng |
100 | __ | |aReddy, Baddam Anantha|eResearcher |
110 | __ | |aDepartment of Electrical and Electronics Engineering|bJawaharlal Nehru Technological University, Hyderabad|dHyderabad|ein|0U-0017 |
245 | __ | |aHigh quality rectifiers with reduced thd for enhanced mains power quality |
260 | __ | |aHyderabad|bJawaharlal Nehru Technological University, Hyderabad|c2012 |
300 | __ | |a137 p.|c-|dNone |
500 | __ | |aReferences p.128 -133 Appendix p.134-137 |
502 | __ | |bPhD|o0503PH0708 |
520 | __ | |aThis thesis presents high-efficiency, high-density, high quality converters with reduced THD for enhanced mains power quality for high-power equipments. The increased applications of non-linear loads and reactive loads make harmonic distortion and over loading of power transmission and distribution networks, a phenomenon that is occurring quite often and the effects of which cannot be ignored since almost all the power transmission and distributionnewlinenetwork components are affected. More harmonics result in more losses, lower efficiency,newlinemore electric energy to be produced and correspondingly more pollution and particularly more carbon dioxide put in to the atmosphere. Lower harmonics and lower reactive power in transmission networks makes not only an economic sense but also a direct solution for sustainable development. Till now the traditional method of current harmonic reduction involved passive filters LC, parallel-connected to the grid, neither convenient nor economical. However, an attractiv |
653 | __ | |aEnhanced |
653 | __ | |aMains |
653 | __ | |aPower |
653 | __ | |aQuality |
653 | __ | |aRectifiers |
700 | __ | |aDas, G Tulasi Ram|eGuide |
856 | __ | |uhttp://shodhganga.inflibnet.ac.in/handle/10603/17273|yShodhganga |
905 | __ | |afromsg |
User Feedback Comes Under This section.